Order Name LAB17777 PARASITE SCREEN, STOOL
Specimen Information
Container | Specimen | Temperature | Collect Vol | Submit Vol | Min Vol | Stability |
EcoFix Vial | Feces | Ambient | Fill EcoFix Vial | Fill EcpFix Vial | 1 mL | 14 days |
EcoFix Vial Kits are available from Lab Customer Service (802) 847-5121.
Collection and Transport of Sample:
- For inpatients, collect sample in a bedpan, avoiding contamination with urine.
- In an outpatient setting, collect specimen in Stool Collection Commode or have the patient put plastic wrap over toilet bowl.
- Add sample to the fill line indicated on the transport vial (approx. 5 mL). Do not add stool above the fill line.
- All vials should be inverted several times so the sample and preservative are well mixed.
Test Schedule / Analytical Time / Test Priority
Monday – Friday / 1 day / Not available STAT
Method
Fluorescent Microscopy
CPT Code(s)
Description | CPT Code |
Concentration for Infectious Agents | 87015 |
Cryptosporidium Exam | 87272 |
Giardia Antigen | 87269 |
Instrumentation
Manual Method
Reference Range
No Giardia Antigen Detection and No Cryptosporidium Antigen Detected
Section
Microbiology-2
Performing Location
University of Vermont Medical Center
Is the UVMMC lab NY State Certified to perform this testing? Yes/No
Yes