Order Name LAB9911 LEUKEMIA/LYMPHOMA PANEL BY FLOW CYTOMETRY

Important Note

*This test is orderable in Cerner as Leukemia/Lymphoma Panel by Flow Cyto UVM

Specimen Information

Container Specimen Temp Collect Vol Submit Vol Min Vol Stability
Sodium Hep (green top) Bone Marrow or Blood Ambient 2 mL 2 mL 1 mL 72 hrs
EDTA (Lav top) Bone Marrow, Blood, or Fluid Ambient 2 mL 2 mL 1 mL 48 hrs
RPMI Fluid, LN*, Tissue*, FNA, BX Ambient N/A N/A N/A 72 hrs
Sterile Container CSF Ambient 2 mL 2 mL 1 mL 48 hrs

Lithium Heparin is NOT an acceptable container type.  ACD has not been validated and is also NOT acceptable.

*Lymph nodes and tissue samples should be cut into small fragments and placed in RPMI to preserve viability. 

Low cellularity samples (ex. CSF) require more sample volume. 

All samples should be kept at ambient temperature after collection and during transport.  Live cells are required for testing, therefore, formalin or other fixatives are NOT acceptable.

Every attempt will be made to accommodate irreplaceable specimens and viability is determined for all but the mosty scant specimens.

Test Schedule / Analytical Time / Test Priority

Monday – Saturday (Scheduled) / up to 4 days / Not available STAT

Method

Flow Cytometry

CPT(s)

CPT Description CPT Code
First Marker 88184
Each additional marker 88185
Flow Cytometry, Interpretation, 2 - 8 Markers (if app) 88187
Flow Cytometry, Interpretation, 9 - 15 Markers (if app) 88188
Flow Cytometry, Interpretation, 16 or more Markers (if app) 88189

 

Instrumentation

BD FACSLyric Flow Cytometers

Reference Range

No Reference Ranges

Section

Immunology

Performing Location

University of Vermont Medical Center

Is the UVMMC lab NY State Certified to perform this testing?  Yes/No

Yes