CBC w/ Diff
Specimen Requirements
Specimen Type: Whole blood
Container/Tube: Lavender top (EDTA)
Specimen Volume: Full tube
Specimen Minimum Volume: 2 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send specimen in original tube.
Stability
24 Hours
Reference Range
Ranges are age- and sex-dependant, refer to report.
Instrumentation
Sysmex XN 1000
Methodology
Automated Cell Counter with reflex to manual differential if indicated.
Includes:
WBC Count
RBC Count
Hemoglobin
Hematocrit
MCV
MCH
MCHC
RDW
Platelet Count
MPV
5-Part Differential
ANC
Test Schedule/Analytical Time/ Test Priority
Daily / Same day / Available STAT
CPT (s)
85025